fix: pin podman storage driver to vfs before any podman command #9

Merged
mlvtito merged 1 commit from fix/image-storage-driver into main 2026-11-15 20:55:55 +00:00
Collaborator

Follow-up to #7: the first dispatch failed at Build and push image with

Error: database graph driver "overlay" does not match our graph driver "vfs": database configuration mismatch

Root cause

podman login (which succeeded — so BOT_TOKEN has the package write scope) was the first podman command: it initialized podman's storage database with the default overlay driver. The subsequent podman build --storage-driver=vfs then refused the mismatch.

Fix

A new step right after the package install writes /etc/containers/storage.conf with driver = "vfs" (plus an explicit runroot) before any podman command runs — login, build and push now share the same storage database. The explicit --storage-driver=vfs on the build stays as documentation.

Wiki updates on merge

Nothing to update in the Wiki (implementation detail of the workflow; the storage choice is documented in the workflow itself).

Follow-up to #7: the first dispatch failed at `Build and push image` with ``` Error: database graph driver "overlay" does not match our graph driver "vfs": database configuration mismatch ``` ## Root cause `podman login` (which succeeded — so `BOT_TOKEN` has the package write scope) was the first podman command: it initialized podman's storage database with the **default `overlay`** driver. The subsequent `podman build --storage-driver=vfs` then refused the mismatch. ## Fix A new step right after the package install writes `/etc/containers/storage.conf` with `driver = "vfs"` (plus an explicit runroot) **before any podman command runs** — login, build and push now share the same storage database. The explicit `--storage-driver=vfs` on the build stays as documentation. ## Wiki updates on merge Nothing to update in the Wiki (implementation detail of the workflow; the storage choice is documented in the workflow itself).
The first podman invocation (login) initialized the storage database
with the default overlay driver, so the subsequent vfs build failed
with a database configuration mismatch. A storage.conf written before
any podman command keeps login, build and push consistent.
mlvtito approved these changes 2026-11-15 20:54:06 +00:00
Sign in to join this conversation.
No reviewers
No milestone
No project
No assignees
2 participants
Notifications
Due date
The due date is invalid or out of range. Please use the format "yyyy-mm-dd".